VFD variable frequency inverter For Heavy Load 55kw 75kw 90kw 110kw
Techincal Parameters:
| Item | Specifiation | |
| Input | Inuput Voltage | 1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
| Allowed Voltage fluctuation range | -15%~10% | |
| Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
| Output | Output Voltage | 3phase:0~input voltage |
| Overload capacity | General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current | |
| Control | Control mode | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) |
| Operating mode | Speed control,Torque control(SVC and VC) | |
| Speed range | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) | |
| Speed control accuracy | ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) | |
| Speed response | 5Hz(V/f) 20Hz(SVC) 50Hz(VC) | |
| frequency range | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) | |
| Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% | |
| Startup torque | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) | |
| Torque control accuracy | SVC:within 5Hz10%,above 5Hz5% VC:3.0% | |
| V/f curve | V / f curve type: straight line, multipoint, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost | |
| Frequency giving ramp | Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s | |
| DC bus voltage control | Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;
Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure
VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault | |
| Carrier frequency | 1kHz~12kHz(Varies depending on the type) | |
| Startup method | Direct start (can be superimposed DC brake); speed tracking start | |
| Stop method | Deceleration stop (can be superimposed DC braking); free to stop | |
| Maincontrol function | Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parameters free switching, software swap output wiring, terminals UP / DOWN | |
| Classification | Parameter group | Page |
| Common parameters | 00:Basic function | Page 37 |
| 01:Frequency source selection | Page 39 | |
| 02:Start and stop | Page 45 | |
| 03:Ramp and S curve | Page 49 | |
| 04: Analog and pulse input | Page 51 | |
| 05:Analog and pulse output | Page 55 | |
| 06:Multi-function Digital input (DI) | Page 56 | |
| 07: Multi-function Digital output(DO) | Page 59 | |
| 08:Digital Output setting | Page 62 | |
| Motor control | 10:Encoder type | Page 65 |
| 11:Motor1 parmeter | Page 66 | |
| 12:Motor1 VFcontrol parameter | Page 68 | |
| 13:Motor1 Vector controlparameter | Page 71 | |
| 14:Torque control | Page 73 | |
| 16:Energy saving control | Page 74 | |
| Display and protection | 20:User-defined parameters | Page 75 |
| 21:Keypad and display | Page 77 | |
| 22:AC Drive configuration | Page 79 | |
| 23:Drive protection function setting | Page 81 | |
| 24:Motor protection parameter | Page 85 | |
| 25:Fault tracking parameter | Page 87 | |
| 26:Fault recording parameter | Page 87 | |
| 27:Monitoring parameter | Page 90 | |
| Communication | 30:Modbus communication | Page 90 |
| 31:Canopen communication | Page 92 | |
| Application | 40:Process PID Function | Page 92 |
| 41:Sleep function | Page 98 | |
| 42:Simple PLC | Page 100 | |
| 43:Programmable delay unit | Page 102 | |
| 44:Comparator and logic unit/controller | Page 104 | |
| 45:Multifunction counter | Page 108 | |
| Motor 2 | 60:Motor2 basic parameter | Page 110 |
| 61:Motor2 parameter | Page 111 | |
| 62:Motor2 VF control parameter | Page 111 | |
| 63:Motor2 vector control parameter | Page 111 |
VEIKONG VFD replace famous brand VFD
|
|